Water Leak Detection System (WLDS)
System Overview
The AGNI Water Leak Detection System (WLDS) is a specialized monitoring and alarm system designed to detect the presence of water or conductive liquids at an early stage preventing costly damage to sensitive areas such as data centers, electrical switch rooms, server racks, raised floors, laboratories, and other application-critical facilities.
The system provides continuous real-time monitoring and issues an immediate alert when water leak is detected, allowing maintenance personnel to respond before a major leak or flooding occurs.
Operating Principle
The WLDS operates using sensing cables or probes that continuously monitor for moisture or conductive liquids along their length or at specific points.
When water or another conductive liquid comes into contact with the sensor, it changes the electrical characteristics (resistance or capacitance) of the sensing element.
The Leak Detection Controller interprets this change and:
- Main control panel
- Detection sensor
- audible and visual alarm
- Displays the exact leak location or zone ID
Provision BMS integration card Sends a signal to the Building Management System (BMS) or Other ALarm Control Panel For integration and remove monitoring.
System Types
There are two primary types of water leak detection systems:
Zone (Non-Addressable) Type
- Monitors individual zones or areas using separate sensing cables or probes.
- Activates an alarm when water is detected within a specific zone.
- Provides simple leak detection — ideal for small or medium-sized installations.
Addressable (Distance-Readable) Type
- Uses a single continuous sensing cable connected to an intelligent system.
- Precisely locates the leak position (in meters) along the sensing cable.
- Supports multiple cable segments for extended coverage.
- Ideal for data centers, large buildings, or critical facilities requiring pinpoint leak location.
System Component & Description
|
Component |
Description |
|
|---|---|---|
|
Leak Detection Control System |
WLD Detection System that monitors sensor cables or prabes, dispalys leak and fault conditions, and interfaces with BMS or alarm systems. |
|
|
Water Leak Sensing Cable |
Polymer-coated, multi-core cable that detects conductive liquids along its entire length resettable after drying. |
|
|
Spot Sensors / Point Probes |
Fixed-point detectors for localized leak monitoring (e.g., under HVAC units or valves). |
|
|
End-of-Line |
Installed at the end of sensing cables to complete the circuit and enable supervision. |
|
|
Interface Module / Relay Output Card |
Provides potential-free contacts for alarm and fault output to external systems (BMS, fire alarm, etc.). |
|
|
Power Supply / Battery Backup |
Ensures continuous operation during power outages; typically 24V DC. Battery Charging Capabilities 7.2ah 12v x 2 nos |
|
|
Mounting Accessories |
Clips, color cable ties, junction boxes, and cable management hardware for proper instalation. |
|
Technical Features
- Continuous real-time monitoring for water leaks or conductive liquid presence.
- High resoltion LCD display with control key pad
- High sensitivity to even small amounts of liquid (as low as 3 mL).
- Addressable systems can locate the leak position within ±1.5 meter accuracy.
- Multi-zone output connection -cable capability for large-area protection.
- LED indicators for Power, Alarm , and Fault conditions.
- Audible and visual alarms with silence/reset controls.
- Available module RS-485 Modbus , BACnet , or dry contact outputs for integration with BMS/FACP.
- Auto-supervision of cable continuity and short/open circuit faults.
- Sensor cables resistant to corrosion, dust, and mechanical wear.
- Modular and expandable system architecture.
- Quick recovery — sensor cables are reusable after cleanup and drying.
Environmental and Electrical Specifications
|
Parameter |
Typical Specification |
|
|---|---|---|
|
Detection Method |
Conductive sensing (resistance change) |
|
|
Sensing Cable Length |
Depending on the requirements |
|
|
Leak Location Accuracy |
±1.5 meter addressable type |
|
|
Alarm Response Time |
< 10 seconds |
|
|
Operating Voltage |
24V DC nominal |
|
|
Operating Temperature |
0°C to 55°C |
|
|
Communication Protocols |
Modbus RTU / BACnet / RS-485 |
|
|
Alarm Outputs |
Relay contacts (NO/NC), 1A @ 30V DC |
|
|
Enclosure Rating |
IP30 (controller), IP65 (sensor junction boxes) |
|
|
Compliance |
CE, RoHS, UL, IEC 61010-1 |
|
Advantages
- Early detection — prevents equipment damage and downtime.
- Continuous coverage — detects leaks anywhere along the cable.
- High accuracy — pinpoint leak location with digital controller.
- Integration-ready — interfaces easily with existing BMS or alarm systems.
- Cost-effective — minimizes repair costs and operational disruptions.
- Flexible installation — suitable for under floor, ceiling, or pipe routing.
- Reusable sensors — low maintenance and long service life.
- Scalable system — expand coverage by adding zones or cables.
Typical Applications
- Data centers and server rooms
- Raised floor systems
- Electrical switchgear and control rooms
- HVAC units and chilled water pipelines
- Laboratories and clean rooms
- Communication and IT facilities
- Industrial equipment enclosures
- Commercial and residential high-rise buildings
Standards and Compliance
The Water Leak Detection System and its components typically conform to:
UL 61010-1
Safety requirements for electrical equipment
IEC 60364
Low-voltage electrical installations
EN 61326
EMC requirements for electrical equipment
CE and RoHS compliance
BS 8489-1
Protection of electrical installations
NFPA 75
Protection of IT and electronic equipment rooms