Agni Veiga Series Intelligent Addressable Active Repeater Panel – 32 Node
The Intelligent Active Repeater Panel – 32 Node from the Agni Veiga Series is a microprocessor-based, intelligent addressable networked repeater designed to operate with a master fire alarm control panel. It provides real-time event monitoring, remote control functionality, and a large graphical LCD display, making it suitable for industrial, commercial, institutional, and government fire alarm applications.
Addressable Fire Alarm Repeater Panel
Built for Distributed Monitoring
Repeater panels can be placed at key locations across a site so maintenance staff and safety officers can act quickly—viewing fire alarm details and finding the exact location of an alarm from anywhere in the building. Instead of running back to the main control room,
The Agni Veiga FAP-2001 Network Active Repeater Panel gives you full system visibility and control wherever you need it. Whether your master fire alarm control panel is in a secured basement plant room or a far wing of the building, this network repeater panel shows live status from the addressable fire alarm system at your security desk, reception lobby, guard station, or emergency command point—so the people who need to respond fastest always know what’s happening.
As an active repeater panel, the FAP-2001 connects over the Veiga RS-485 network (network card FAP-3002 required) and supports up to 32 nodes across segments of up to 1.2 km each—making it a good fit for a single building or a large campus network of fire alarm control panels. Built in a strong 1.2mm mild steel IP30 enclosure with a soft-touch keypad and a large backlit graphical LCD, this fire alarm repeater panel is built to perform well in reception areas, hospital nursing stations, factory control rooms, and government security checkpoints — a dependable fire repeater panel for places where reliability matters most.
Power comes directly as 28V DC from the main panel’s auxiliary supply or an SMPS repeater location—making installation easier for any addressable fire alarm repeater panel setup. A 4,000-event, time-and-date-stamped log gives facility teams a full audit trail for compliance reporting and post-incident review, turning routine fire alarm monitoring into clear, documented records.
As essential fire alarm equipment for any multi-building or multi-floor site, the FAP-2001 meets EN54-2, EN54-4, and IS 2189-2175:1988 standards and carries CE and ERTL/NABL accreditation—making it a trusted repeater panel for fire alarm system installations and a reliable addressable fire panel choice in ministry offices, hospitals, university campuses, and industrial townships across India.
Whether you’re upgrading an existing fire alarm panel network or planning a new addressable fire alarm control panel installation from scratch, the FAP-2001 brings the same intelligence and control to every secondary monitoring point on site.
Compliance & Certifications
CE
European Conformity
EN54-4 | EN45-2
European Norms
UL 217:2024
Functionality Compliance
IS 2189: 2022
NABL Laboratories Test Certificate
ERTL North (Govt. India)
functional test certificate
Code of Practive
INDIA- BIS | NBC
Approved Department
Government of India
Department of CPWD / PWD
Complied with CPWD DSR
Our fire safety engineers respond within 2 hours with competitive pricing for your project
Call: 9811522993 / 9811554440
Choose the Right Addressable Panel for Your Installation
The Veiga Series variants are available in customisable loop configurations, based on the same intelligent addressable microprocessor platform. The system supports loop-powered sounders, strobes, detector sounder beacon bases, manual call stations, monitor modules, and zone monitor modules — easy to build hybrid fire alarm system applications. Select the model that best matches your site’s device capacity and future expansion requirements.
Compatibility
|
1 Loop Panel |
VEIGA-FAP-1001 |
|
2 Loop Panel |
VEIGA-FAP-1002 |
|
4 Loop Panel |
VEIGA-FAP-1004 |
| Repeater Panel |
VEIGA-FAP-2001 |
Full Technichal Specificaiton - Agni Veiga Series FACP
All specifications for the analogue addressable fire alarm system, covering general performance, power supply, inputs/ outputs, and mechanical/ compliance other parameters.
|
PARAMETER |
Specification |
|---|---|
|
Product Type |
Intelligent Addressable Active Repeater Panel |
|
Part Number |
VEIGA-FAP-2001 |
|
Power Supply |
28V DC externally from main control panel |
|
Current Consumption |
100 mA max |
|
Network Protocol |
Agni Veiga Protocol |
|
Network Distance |
Maximum Length: Up to 2,000 m (6,562 ft / 1.24 miles) per channel using 12 AWG (3.1 mm²) twisted-pair cable, subject to cable copper conductor resistance, joint quality, and site installation conditions. |
|
Programmable Company Logo |
Yes |
|
Parameter |
Specification |
|---|---|
|
Enclosure Material |
1.2 mm Mild Steel |
|
Protection Rating |
IP30 |
|
Finish |
Powder-Coated – Colour RAL ECRAL7035UL035L Interpon (Red/Blue Fascia Options) |
|
Front Fascia |
Soft Touch Key Pad / Standard Sticker Label – Blue or Red |
|
System Internal |
Accessibility front door locking arrangement |
|
Dimensions |
300 W × 202 H × 58 D (mm) |
|
Cable Entry |
Via 20 mm knockouts – Top and Rear of Cabinet |
|
BIS Standard |
IS 2189:2022 – Code of Practice / NABL Tested |
|
Certification |
EN54-4 | EN54-2 , CE Marked (European noms & Conformity} |
|
Lab Tested |
ERTL North (Govt. India) |
|
Compliance Standard |
UL 217|2024 (functionality Compliance) |
|
Warranty |
12 Months |
|
Front Label |
Standard sticker label (Blue / Red) |
|
Veiga Seires |
Part Number |
|---|---|
|
1 to 4 Loop Addressable Fire Alarm Control Panel |
VEIGA-FAP-1001 / VEIGA-FAP-1002 / VEIGA-FAP-1004 |
|
Network Active Repeater Panel |
VEIGA-FAP-2001 |
|
Backnet/ModBus Card |
FAP-ModBus |
|
RS-485 Network communication card |
VEIGA-FAP-3002 |
|
Handheld Programmer |
VEIGA-IND-ALPU1000 |
|
Addressable Photothermal(Multi) Detector |
VEIGA -IND-OH |
|
Addressable Optical Smoke Detector |
VEIGA -IND-OP |
|
Addressable ROR cum Fixed Temperature |
VEIGA -IND-HT |
|
Stander Detector Base |
IND-MB |
|
Intelligent Addressable Loop Sounder Base |
IND-S2MB / IND-SV2MB |
|
Isolator Base |
IND-ISO-B (Comming Soon) |
|
Intelligent Addressable Loop Sounder cum Bcecon |
IND-WSM+LPM |
|
Intelligent Addressable Manual Call Point |
IND-ALCP100 |
|
Addressable Input/Monitor Module |
IND-VMI100 |
|
Addressable Control Module |
IND-VMIC-120 |
|
Addressable Zone Monitor Module |
IND-VMCZ100 |
|
Addressable Isolator Module |
IND-LVMX100 |
How it Works
How does the Agni Veiga Intelligent Active Repeater Panel Work?
The Intelligent Active Repeater Panel – 16 Node works by receiving real-time fire alarm data from a master fire alarm control panel and displaying it remotely. It allows authorized users to monitor events and perform essential control actions without accessing the main panel.
Application & Solution
- Commercial Office Building
- Hospital and Healthcare Facility
- Industrial Plant
- Educational Institution
The Agni Veiga Series Stand Out For
An intelligent addressable fire alarm system designed for many controlled operation, with firmware that complies with national and international standards. The system incorporates multiple redundancy features, simplified maintenance, and long-term operational stability.
Connection to the Master Fire Alarm Control Panel
The repeater panel connects to the master addressable fire alarm control panel via the Agni Veiga RS-485 network protocol using a Veiga-FAP-3002 network card. Once connected, it continuously communicates with the main panel over the fire alarm network.
Real-Time Event Display
All system events — fire alarms, faults, isolations, and system status — are instantly displayed on the large 320×240 graphical LCD with clear text and symbols. The fire alarm repeater panel mirrors the master panel display in real time.
Event Storage and Audit Log
The fire addressable panel stores up to 4000 events in internal memory. Each event is automatically recorded with a time and date stamp, enabling easy review for audits, insurance claims, and troubleshooting.
Remote Fire Alarm Control
Authorised users operate key emergency functions directly from the active repeater panel: Evacuate · Mute Buzzer · Silence Alarm · Reset System. These commands are securely transmitted to the master fire alarm control panel.
Continuous System Supervision
The addressable fire alarm repeater panel continuously monitors network integrity and system health through built-in earth fault monitoring, detecting wiring or grounding issues before they affect the fire alarm system.
Stable Power from Control Panel / UPS
The panel operates at 28V DC drawn from the main control panel's auxiliary supply or a UPS, ensuring fire alarm monitoring continues uninterrupted during mains power failures without the need for an internal battery.
Product in One Line
An intelligent repeater panel allows real-time monitoring and mirrors the master fire alarm control panel, enabling authorized control from multiple locations without visiting the main panel.
Applications of the Veiga Series Addressable Active Repeater Panel
Hospital & Healthcare
Low false-alarm rate matters where patient evacuation is disruptive and high-risk.
Industrial Facilities
DRC protection handles dust and process contaminants common on production floors.
Commercial Buildings
Offices, malls, and corporate towers needing reliable, code-compliant detection.
Electrical & Equipment Rooms
Dual-criteria sensing catches both smouldering cable fires and fast-developing heat events.
Frequently Asked Questions
Common questions about the Agni Veiga Series intelligent Addressable Active Repeater Panel.
An Intelligent Active Repeater Panel is a networked display and control unit that mirrors all events from a master fire alarm control panel. It shows alarms, faults, and system status in real time and allows authorised users to perform remote actions — including evacuation, silence, mute buzzer, and reset — without accessing the main panel. It is a key component of any distributed addressable fire alarm system.
The fire alarm repeater panel connects to the master fire alarm control panel through the Agni Veiga Protocol RS-485 network over distances up to 1.2 km per segment. It continuously receives system data, displays all events on a 320×240 graphical LCD, and allows remote control — including evacuate, silence, mute, and reset — without affecting the core processing of the main addressable fire alarm control panel.
Yes. The Agni Veiga FAP-2001 includes built-in earth fault monitoring that continuously supervises network wiring. This detects grounding faults early, improving the overall reliability of the fire alarm system and reducing downtime.
No. A fire alarm repeater panel does not independently process alarms. It only displays events and forwards control commands to the master fire alarm control panel, which retains all processing and decision-making authority. The repeater provides a remote window into the master panel for monitoring and basic control operations.
The Agni Veiga FAP-2001 Network Active Repeater Panel supports communication distances of up to 1.2 km per network segment using the Agni Veiga Protocol over RS-485 wiring, making it ideal for medium and large fire alarm installations across spread-out facilities.
The FAP-2001 conforms to EN 54-2 and EN 54-4 fire alarm control panel standards, the IS 2189 Indian standard for fire detection and alarm systems, and carries CE certification. It is independently tested by ERTL/NABL accredited laboratories. This makes it suitable for government CPWD projects, institutional buildings, and export markets requiring European standard fire alarm equipment.
Active Repeater Panel Max 16 Node
Agni Veiga Intelligent Active Repeater Panel 16 Node by Agni Veiga with graphical LCD, remote controls, 4000-event log, EN54 & IS 2189 compliant.