Agni Veiga Intelligent Addressable Detector Mounting Standard Base

The Detector Mounting Standard Base is a durable mounting solution for Agni Veiga Series intelligent addressable detectors, designed for secure ceiling installation, easy wiring, and reliable detector locking.

Description

The Detector Mounting Standard Base from Agni Veiga Series – Intelligent Addressable range is designed to provide a reliable and secure interface between the detector dead and the mounting surface. 
This base allows wiring to be completed during the initial installation stage, even before the detector is installed. Once wiring is finished, the detector head is simply twisted and locked into the base, ensuring fast installation and simplified maintenance. 

Manufactured using durable plastic, the base is suitable for surface mounting directly to ceilings or standard conduit boxes. It is equipped with robust screw terminals and SEMS screws, ensuring firm and long-lasting electrical connections. 
An optical detector locking mechanism helps prevent unauthorized removal of the detector head. The base also supports remote indicator connection, allowing a remote LED indicator to provide visual alarm indication when the detector is installed in concealed locations such as false ceilings. 

The mounting base is typically compatible with smoke detectors, heat detectors, and multi-sensor detectors used in intelligent addressable fire alarm systems. 

Job to be Done

Primary Job

Install fire alarm detectors securely, quickly and reliable while allowing pre-wiring, easy maintenance, and system integrity in intelligent addressable fire alarm systems.

Safety Job

It keeps fire alarm detectors securely mounted, electrically reliable, tamper-resistant, and visible through remote indicators, ensuring continuous fire detection and system safety.

Functional Jobs

Securely mounts detectors, provides electrical connections, supports pre-wiring, enables twist-and-lock installation, and allows safe maintenance without wiring disruption.

How it Works

How does the Agni Veiga Detector Mounting Standard Base Work?

The Detector Mounting Standard Base (IND-MB) functions as the mechanical and electrical interface between the fire alarm detector and the mounting surface. It enables safe wiring, secure detector installation, and reliable system operation. 

Application & Solution

  • Office Building with False Ceiling 
  • Commercial Mall Installation
  • Industrial Facility with Restricted Access 
  • Maintenance & Replacement Scenario 

Application & Solution

  • Office Building with False Ceiling 
  • Commercial Mall Installation
  • Industrial Facility with Restricted Access 
  • Maintenance & Replacement Scenario 

How does the Agni Veiga Detector Mounting Standard Base Work?

1. Base Installation on Surface

The mounting base is first fixed directly onto the ceiling or a standard conduit box using appropriate fasteners.

2. Loop Wiring Connection

Fire alarm loop cables are connected to the base terminals using robust screw terminals with SEMS screws. This ensures secure and stable electrical connections.

3. Remote Indicator Wiring (Optional)

If required, a remote indicator LED or compatible device is connected to the designed terminals on the base.

4. Initial System Wiring Completed

All wiring is completed during the first installation stage, even before the detector head is installed.

5. Detector Head Mounting

The detector head is aligned with the base and twisted into position, locking it securely in place.

6. Detector Locking (Optical)

An optical locking mechanism prevents unauthorized removal of the detector head after installation.

Product in One Line 

The Detector Mounting Standard Base helps installers pre-wire, securely mount, and protect fire alarm detectors while enabling for installation, easy maintenance, and reliable system performance.

Technical Specification

PARAMETER

Specification

Product Type

Intelligent Addressable Detector Mounting Standard Base

Model

IND-MB

Series

Agni Veiga Series

System Type

Intelligent Addressable

Mounting Type

Surface mounting

Mounting Location

Ceiling / Standard conduit box

Material

Durable plastic

Wiring Terminals

Robust screw terminals with SEMS screws

Detector Locking

Optical locking mechanism

Remote Indicator Support

Yes

Remote Output Capability

Available as standard feature

Compatible Detectors

Smoke, Heat & Multi-Sensor Detectors

Installation Method

Twist & lock detector head

Application

Fire alarm detection systems

FAQ

What is a Detector Mounting Standard Base?

A Detector Mounting Standard Base is a component used to securely mount fire alarm detectors to ceilings or conduit boxes. It provides electrical connections and a locking interface for the detector head.

The Detector Mounting Standard Base is used to install Agni Veiga Series Intelligent Addressable detectors. It acts as an intermediary between the ceiling surface and the detector head, simplifying installations and maintenance.

The Detector Mounting Standard Base connects the fire alarm detector to the ceiling, allows wiring before detector installation, and securely locks the detector in place for reliable operation.

Yes. Correct cable polarity must be ensured during installation, especially when connecting remote output devices. 

Intelligent Addressable Detector Mounting Standard Base 

Agni IND-MS Detector Mounting Standard Base for intelligent addressable fire alarm systems. Durable design, secure wiring, remote indicator support.Â