Fire Alarm Accessories
Showing 1–12 of 20 results
Agni Flasher/Strobe
Agni-407
Exclusive range of Fire Alarm Strobe for addressable & Conventional use with Red MS type Housings. Wall mounted type. The Fire Alarm Strobe is a device that produce Flashing when Manual Call Point & Detector sense any kind of fire activity. It alert everyone including deaf inside the building.
Agni, Conventional Heat Detectors
Agni 203
AGNI conventional heat detectors are state-of-the- art detectors suitable for connection to conventional fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept conventional type detectors1.An electronic thermostat sensor provides sensitive rate of rise alarm operation or fixed-temperature operation when the response threshold value is exceeded .The range of conventional detectors provides fire detection and alarm system designers with a Standards- compliant economical heat detector for property protection applications2 where smoke or multi-sensor detectors may not suitable due to environmental conditions.
Download Datasheet
Agni, Hooter Cum Speaker MS Body
AGNI-404
Exclusive range of Fire Alarm Hooter(Sounder) Conventional use with made out of 16/18 SWG CRCA Sheet duly powder coated with PO Red Colour. The wall mounted medium frequency hooter designed as per NFPA-72 to complete the demand of Fire Alarm systems in several areas of residential, commercial & Industrial application. The Fire Alarm Hooter is a device that produce sound when Manual Call Point & Detector sense any kind of fire activity. It has dual tone sound and it is enough to make alert everyone inside the building.
Agni, Manual Call Point MS Body
AGNI-301
Conventional manual call point is an emergency alerting device which can be activated by pressing a transparent plastic window on its front side. The call point once activated can be reset by using a key with the device. Designed for use with conventional fire alarm control panels and alarm loop by installing the module conventional zone module. This allows the fire alarm control panel to monitor the conventional call point
devices.
Agni, ROR Heat Detector
A rate-of-rise (ROR) heat detector measures the rate at which air temperature changes during a fire. ROR detectors operate by detecting a rapid rise in element temperature of 6.7° to 8.3°C (12° to 15°F) increase per minute. When the temperature rises to a level exceeding a predetermined degree, the ROR detector signals
Agni, Simplex Type Talkback Slave Station
Agni Slave Talk-back Unit Can Communicate With Main Talk-back Master Panel. At Slave Unit After Pressing Ptt Switch Signal Comes On Main Master Panel Control Room Can Receive Call By Pressing Ptt Switch At Master Panel, and By This Indication Also Know Which Floor/zone Number Or Location Slave Unit Is Calling To Master Station. This Is A Simples Mod Of Communication.
Agni, Smoke Detector
Agni 202
- Advanced detection and discrimination algorithms
- Easy installation and maintenance
- Super sleek low- prole housing design
- Durable sensor head, no need for replacement
- SMD circuit board design-satisfactory quality and reliability guaranteed
- Integrated heat detector for SD 388-2H and SD 388-4H models
- N/C (normal/close)-N/O (normal/open)selectable relay output
- AR (Auto Reset) function for security systems (optional for 4 wire models)
- Five-year limited warranty
- Size: 102mm diameter with 43mm height only
Agni, Sounder Cum Strobe
Agni-406
Exclusive range of Fire Alarm Sounder Cum Strobe for addressable & Conventional use with Red ABS type plastic Housings. Wall mounted medium frequency Sounder Strobe designed as per NFPA-72 to complete the demand of Fire Alarm systems. The Fire Alarm Sounder Strobe is a device that produce sound & Flashing when Manual Call Point & Detector sense any kind of fire activity. It has dual tone sound and it is enough to make alert everyone inside the building.