X Hybrid 2 to 8 Zone Conventional Fire Alarm Control Panel
The AGNI-1100 X Hybrid is a microprocessor-based conventional fire alarm panel for small and medium-sized buildings. It supervises every zone for open and short circuits, shows each zone on its own LED, and links to repeater panels over RS-485.
Conventional fire alarm control panel built for reliability
The AGNI-1100 is a microprocessor-based conventional fire alarm panel from Agni Instruments Engineers India Private Limited, designed for small and medium-sized buildings that need reliable, zone-level fire detection. It is part of the X Hybrid series and comes as a 2 zone, 4 zone, 6 zone or 8 zone fire alarm control panel (AGNI-1102, 1104, 1106 and 1108). Detectors, manual call points and supervisory devices wired in each zone report together, so staff can see at once which part of the building is in alarm.
The panel runs on a high-performance microprocessor with an onboard 16 × 2 LCD that shows live system status and diagnostics. Every zone also has its own LED, giving operators an at-a-glance view of whether a zone is healthy, in fire, faulted or isolated. The panel continuously supervises all field wiring for open and short circuit conditions, along with zone health, battery condition, the mains and battery supply, and the communication link. Faults are therefore caught and reported early, before they can compromise protection during a real emergency.
When a detector or manual call point signals a fire, the AGNI-1100 acts immediately. It drives the common sounder output so that every connected notification appliance sounds, and it enables the zone-wise notification outputs for zone-level sound annunciation. At the same time it switches the fire relay and shows visual and audible alarms on the front panel. Three potential-free relays, for fire, open circuit and short circuit, let the panel interface with building management systems, auto-dialers, hooters, suppression systems and public address equipment. This makes it easy to include in a wider building safety setup, and the RS-485 interface allows repeater panels to be added for remote annunciation of fire and fault conditions.
The Fire alarm panel smart power management algorithm manages charging, backup performance and load distribution on both mains and battery, while deep discharge protection stops the standby batteries from being drained too far during long power failures, so they recharge properly when supply returns. Battery polarity protection also guards against a common installation mistake by preventing damage if the terminals are connected the wrong way round.
The panel sits in a heavy-duty 1.8 mm sheet metal enclosure with a polycarbonate front door secured by lock and key, so the display stays visible while the controls are protected from tampering. As a conventional fire alarm manufacturer in India with in-house design, testing and production in New Delhi since 1989, Agni supports the AGNI-1100 with OEM and ODM supply, training and warranty-backed service, and exports it to partners abroad.
Certifications & Compliance
CE
European Conformity
EN54-4 | EN45-2
European Certification
UL 217:2024
Functionality Compliance
IS 2189: 2022
NABL Laboratories Test Certified
ERTL North (Govt. India)
Functional Test Certified
Standard Code of Practice
INDIA- BIS | NBC
Approved Department
Government of India
Department of CPWD / PWD
Complied with CPWD DSR
Full Technichal Specificaiton - Hybrid
|
Parameter |
Specification |
|---|---|
|
Control Type |
Conventional |
|
Part Number |
AGNI-1102 | AGNI-1104 | AGNI-1106 | AGNI-1108 |
|
Standards |
IS 2189:1999 | EN 54 |
|
Zones |
2 to 8 conventional zones |
|
CPU |
8-bit peocessor |
|
Dispaly |
16×2 LCD character dispaly |
|
Zone scan |
Every 90 seconds, automatic |
|
Zone inslation |
Internal 4-way DIP switch |
|
Enclosure |
CRCA sheet steel, powder-coated |
|
Cabinet Size (H × W × D) |
(270 × 400 × 110 mm) |
|
Parameter |
Specification |
|---|---|
|
Mains Supply |
230 VAC |
|
System operating voltage |
24 V DC to 35 V DC |
|
Battery backup |
2 × 12 V 7.2 Ah sealed lead-acid, in series (24 V DC) |
|
Charging |
26.6 V DCk international inbuilt charger |
|
Fuses |
AC 0.5 A | DC 1.5 A | Battery 3.0 A |
|
Parameter |
Specification |
|---|---|
|
Zone detection voltage |
23.5 V |
|
End-of-line resistor |
4.7 kΩ per zone |
|
Compatible devices |
Standard smoke and heat detectors, hooters and sounder of other brands |
|
Relay outputs |
Fire and Fault, each C / NO / NC |
|
Sounder outputs |
Common hooter output; zone-wise hooter relay output |
|
Cable entry |
7 knockouts, 20 / 25 mm (top, bottom, rear) |
|
Conventional Seires |
Part Number |
|---|---|
|
X Hybrid 2, 4, 6, 8 Zone Control Panel |
AGNI-1102 | AGNI-1104 | AGNI-1106 | AGNI-1108 |
|
Multi Detector |
AGNI-201 |
|
Photoelectric Somke Detector |
AGNI-204 |
|
Heat Detector |
AGNI-205 |
|
Duct Smoke Sampling Detector |
AGNI-208 |
|
Industrial Heat Detector (Prob) |
AGNI-207 |
|
CO Gas Detector |
AGNI-CO |
|
LPG Gas Detector |
AGNI-LPG |
|
CNG Gas Detector |
AGNI-CNG |
|
PNG Gas Detector |
AGNI-PNG |
|
Electronic Hooter Cum Sounder - MS |
AGNI-403 |
|
Electornic Hooter Cum Sounder - ABS |
AGNI-408 |
|
High Intensity Hooter |
AGNI-418 |
|
LED Sounder Cum Strobe ABS |
AGNI-405 |
|
LED Sounder Cum Strobe MS |
AGNI-406 |
|
Xenon Sounder Cum Strobe ABS |
AGNI-407 |
|
LMT Hooter Cum Speaker MS |
AGNI-404 |
|
PA LMT Hooter cum Speaker ABS |
AGNI-409 |
|
Exit Point Navigator |
AGNI-EPN-918 |
|
Manual Call Point MS Body |
AGNI-301 |
|
Manual Call Point ABS Body |
AGNI-302 |
|
Chain & Hammer |
AGNI-CH35 |
|
Response Indicator Wall Mounted ABS Body |
AGNI-501 |
|
Response Indicator ABS Ceiling Mounted |
AGNI-502 |
|
Response Indicator Wall Mount MS Body |
AGNI-503 |
|
AC Interposing Relay Module |
AGNI-704-AC-2RC |
The Agni Conventional X Hybrid Fire Alarm Panel Stand Out For
Fully supervised zones
Open circuit and short circuit detection on every zone, with continuous supervision of field wiring and panel electronics.
Zone-wise annunciation
Independent LED per zone, plus a 16 × 2 LCD for live status and diagnostics.
Common and zone NAC outputs
One common sounder output plus zone-wise NAC outputs for zone-level sound annuniciation.
Three dry contact relays
Fire, Open and Short relays for BMS, auto-dialers, hooters.
RS-485 networking
Repeater panel connectivity with a green LED confirming a healthy link.
Battery protection
Polarity protection and deep discharge protection extend standby battery life.
Product in One Line
The AGNI-1100 is a microprocessor-based conventional fire alarm panel in 2, 4, 6 and 8 zone models, with supervised zones, a 16 × 2 LCD, three dry relays and RS-485 repeater connectivity, made in India by Agni Instruments.
Frequently Asked Questions
It is a control panel that monitors detectors grouped into zones. When one device in a zone detects fire, the panel shows that zone in alarm, not the individual device.
Yes, The Panel works with standard conventional smoke detectors, heat detectors, hooters and sounders, with a 4.7 kΩ end-of-line resistor on each zone.
Yes, Walk test mode lets you check individual detectors and call points during occupied hours without starting a full evacuation.
Yes. Agni Instruments Engineers India Private limited has manufactured fire alarm systems in New Delhi since 1989 and exports to more than 14 countries.
Yes, Agni Instruments Engineers India Private Limited has manufactured fire alarm sysetms in New Delhi since 1989 and exports to 14+ countries.
Conventional Fire Alarm Panel 2-8 Zone | AGNI-1100 X Hybrid
AGNI-1100 conventional fire alarm panel, 2 to 8 zones, from a fire alarm panel manufacturer in India. LCD, RS-485, 3 relays.