Agni 10 Zone Fire Alarm Panel

10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required – 2 Nos.(one to act as standby)

Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos. talk back unit -1 set.

Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc.
complete as required- 1 No.

Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as
required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 60 AH each sealed maintenance free batteries -1 set. main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections,interconnections etc complete as required.

 

Download Datasheet

Agni Flasher/Strobe

Agni-407

Exclusive range of Fire Alarm Strobe for addressable & Conventional use with Red MS type Housings. Wall mounted type. The Fire Alarm Strobe is a device that produce Flashing when Manual Call Point & Detector sense any kind of fire activity. It alert everyone including deaf inside the building.


Download Datasheet

 

Agni Hybrid Fire Alarm Control Panel

Agni 1012

AGNI HYBRID fire alarm control panels demonstrate that value doesn’t have to come at the expense of quality, and that small building owners don’t have to settle for second-rate fire protection. With AGNI HYBRID comes a full lineup of advanced features designed expressly for new and retrofit projects that cry out for simplicity, yet need state of- the-art protection. These two attributes aren’t mutually exclusive in a fire alarm control panel. At least not now.


Download Datasheet

 

Agni Instruments Engineers (I) Pvt. Ltd.

There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don’t look even slightly believable. If you are going to use a passage of Lorem Ipsum, you need to be sure there isn’t anything embarrassing hidden in the middle of text. All the Lorem Ipsum generators on the Internet tend to repeat predefined chunks as necessary, making this the first true generator on the Internet. It uses a dictionary of over 200 Latin words, combined with a handful of model sentence structures, to generate Lorem Ipsum which looks reasonable. The generated Lorem Ipsum is therefore always free from repetition, injected humour, or non-characteristic words etc.

Agni, Conventional Heat Detectors

Agni 203

AGNI conventional heat detectors are state-of-the- art detectors suitable for connection to conventional fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept conventional type detectors1.An electronic thermostat sensor provides sensitive rate of rise alarm operation or fixed-temperature operation when the response threshold value is exceeded .The range of conventional detectors provides fire detection and alarm system designers with a Standards- compliant economical heat detector for property protection applications2 where smoke or multi-sensor detectors may not suitable due to environmental conditions.

Download Datasheet

Agni, Hooter Cum Speaker MS Body

AGNI-404

Exclusive range of Fire Alarm Hooter(Sounder) Conventional use with made out of 16/18 SWG CRCA Sheet duly powder coated with PO Red Colour. The wall mounted medium frequency hooter designed as per NFPA-72 to complete the demand of Fire Alarm systems in several areas of residential, commercial & Industrial application. The Fire Alarm Hooter is a device that produce sound when Manual Call Point & Detector sense any kind of fire activity. It has dual tone sound and it is enough to make alert everyone inside the building.


Download Datasheet

Agni, Manual Call Point MS Body

AGNI-301

Conventional manual call point is an emergency alerting device which can be activated by pressing a transparent plastic window on its front side. The call point once activated can be reset by using a key with the device. Designed for use with conventional fire alarm control panels and alarm loop by installing the module conventional zone module. This allows the fire alarm control panel to monitor the conventional call point
devices.


Download Datasheet

Agni, ROR Heat Detector

A rate-of-rise (ROR) heat detector measures the rate at which air temperature changes during a fire. ROR detectors operate by detecting a rapid rise in element temperature of 6.7° to 8.3°C (12° to 15°F) increase per minute. When the temperature rises to a level exceeding a predetermined degree, the ROR detector signals