Shop
-
Aspiration system -
Direct Release Clean Agent -
Emergency Alarm & Evacuation Switch -
Emergency Voice Communication System -
Equipment Rack -
FAS with P A & Talkback System (CPWD DSR Specification) -
FAS with P A System (BSNL Specification) -
Fire Alarm Accessories -
Fire Alarm Control System -
Fire Safety -
Gas Relese System -
Gas Suppression System -
Hooter/Hooter Flasher/Hooter cum Speaker -
Laser Cutting & Etching -
Linear Heat Detection System -
Multi Tone Sounder -
PA System -
PA/Server Equipment Rack -
Public Address / Notification Voice Announcement -
Software -
Sprinkler Annouciation Panel -
Sprinkler Announciation Panels -
Uncategorized -
UTC/GST -
Water Leakage Detection Sounder (WHITE) -
Water Leakage Detection System Cable -
Water leakage System -
X Sense Panel 2-60 Zone Detection Zone
Showing 25–36 of 79 results
Agni Veiga Series Intelligent Addressable Sounder Strobe Base
The IND-SV2MB or IND-S2MB Sounder Strobe Base is a low-profile, intelligent addressable audio-visual base designed for use with Agni Veiga Series detectors. It delivers reliable audible and visual alerts with low current consumption, making it ideal for indoor fire alarm applications.Â
Agni Veiga Series Intelligent Addressable Thermal Fixed Temperature Heat Detector
Intelligent addressable thermal detector combining rate-of-rise and fixed temperature detection for early and reliable fire alerts in challenging environments.Â
Agni Veiga Series Intelligent Isolator Module
The Agni Veiga Intelligent Isolator Module (IND-LVMX-100) is designed to Protect intelligent addressable A Class A fire alarm loop with fault isolators provides maximum redundant, bidirectional wire path that returns to the panel. ensuring uninterrupted system operation and fast fault recovery.
Agni X Hybrid 2 to 8 Zone Fire Alarm Control Panel
The AGNI-1100 X Hybrid is a microprocessor-based conventional fire alarm panel for small and medium-sized buildings. It supervises every zone for open and short circuits, shows each zone on its own LED, and links to repeater panels over RS-485.
Agni, Conventional Heat Detectors
Agni 203
AGNI conventional heat detectors are state-of-the- art detectors suitable for connection to conventional fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept conventional type detectors1.An electronic thermostat sensor provides sensitive rate of rise alarm operation or fixed-temperature operation when the response threshold value is exceeded .The range of conventional detectors provides fire detection and alarm system designers with a Standards- compliant economical heat detector for property protection applications2 where smoke or multi-sensor detectors may not suitable due to environmental conditions.
Download Datasheet
Agni, Hooter Cum Speaker MS Body
AGNI-404
Exclusive range of Fire Alarm Hooter(Sounder) Conventional use with made out of 16/18 SWG CRCA Sheet duly powder coated with PO Red Colour. The wall mounted medium frequency hooter designed as per NFPA-72 to complete the demand of Fire Alarm systems in several areas of residential, commercial & Industrial application. The Fire Alarm Hooter is a device that produce sound when Manual Call Point & Detector sense any kind of fire activity. It has dual tone sound and it is enough to make alert everyone inside the building.
Agni, Manual Call Point MS Body
AGNI-301
Conventional manual call point is an emergency alerting device which can be activated by pressing a transparent plastic window on its front side. The call point once activated can be reset by using a key with the device. Designed for use with conventional fire alarm control panels and alarm loop by installing the module conventional zone module. This allows the fire alarm control panel to monitor the conventional call point
devices.
Agni, ROR Heat Detector
A rate-of-rise (ROR) heat detector measures the rate at which air temperature changes during a fire. ROR detectors operate by detecting a rapid rise in element temperature of 6.7° to 8.3°C (12° to 15°F) increase per minute. When the temperature rises to a level exceeding a predetermined degree, the ROR detector signals